Continuous Positive Airway Pressure (CPAP)

  • Adopting the special designed air pump, RE mart TM provides users stable 2-20hPa therapy pressure.
  • Ramp capabilities allow a 0-60 minutes time period with adjustable ramp starting pressure.
  • Inspiration trigger for auto start-up
  • Automatic stop after put off mask
  • Alarm when accidental power-off
  • In time alert function when mask and/or tubing off-line
  • Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.
  • Unique Delay-off feature protects RE Smart TM from humidity hazard.
SKU: SAMSAC008 Category:

Description

Description

Continuous Positive Airway Pressure (CPAP)

Reliable stability

  • Adopting the special designed air pump, RE mart TM provides users stable 2-20hPa therapy pressure.
  • Ramp capabilities allow a 0-60 minutes time period with adjustable ramp starting pressure.
  • Inspiration trigger for auto start-up
  • Automatic stop after put off mask
  • Alarm when accidental power-off
  • In time alert function when mask and/or tubing off-line
  • Automatic leakage and altitude compensation ensure the therapy accuracy anywhere.
  • Unique Delay-off feature protects RE Smart TM from humidity hazard.

Ergonomic design

  • Backlit LCD display for operation in dark
  • Lighted user buttons with lockup capability
  • Integrated designed InH2TM heated humidifier
  • Smart Heater automatic restarts after short term break.
  • Patented anti-countercurrent water tank
  • DC 24V powered and infrared controlled humidifier make user safe and comfortable
  • Low Noise device

Technical Specifications:

Device Size                                 220 × 194 × 112 mm
Dimensions:                                 313 × 194 × 112 mm (with InH2TM heated humidifier)
Weight:                                  < 2 kg
Product Use, Transport and Storage
Operation                              Transport and Storage
Temperature:                        5 to 40℃                                  -20 to 55℃
Humidity:                               ≤80% Non-condensing            ≤93% Non-condensing
Atmospheric Pressure:        86 to 106 kPa                           N/A
Standard Compliance
IEC 60601-1 General Requirements for Safety of Medical Electrical Equipment
ISO 17510 Sleep Apnoea Breathing Therapy
Mode of Operation Continuous
AC Power Consumption       100 – 240VAC, 50/60Hz
Type of Protection against Electric Shock:              Class II Equipment
Degree of Protection against Electric Shock:         Type BF Applied Part
Degree of Protection against Ingress of Water:    IPX0 – Ordinary Equipment
Pressure Range:                                                         2 to 20 hPa (in 0.5 hPa increments)
Pressure Stability:                                                       2 to 20 hPa (±0.5 hPa)
Sound Pressure Level:                                              <30 dB
Maximum Flow:                                                          >15 LPM
Pressure Display Accy.:                                             ±0.5 hPa